Investigation of the Joint Headquarters Rheindahlen (JHQ)
Investigation of 507 individual residential buildings (standard buildings) for pollutants of the parameters asbestos, synthetic vitreous fiber (SVS), polycyclic aromatic hydrocarbons (PAH’s), polychlorinated biphenyls (PCB), wood preservatives (lindane, pentachlorophenol PCP, dichlorodiphenyltrichloroethane DDT, PCB and PAH’s), heavy metals, wood infestation, adsorbable organically bound halogens (AOX) and mineral oil hydrocarbons
Investigation of 307 individual special buildings (specific buildings) for pollutants of the parameters asbestos, synthetic vitreous fiber (SVS), polycyclic aromatic hydrocarbons (PAH’s), polychlorinated biphenyls (PCB), wood preservatives (lindane, pentachlorophenol PCP, dichlorodiphenyltrichloroethane DDT, PCB and PAH’s), heavy metals, wood infestation, adsorbable organically bound halogens (AOX) and mineral oil hydrocarbons
- Investigation of 38.3 km of asphalt driving surfaces for polycyclic aromatic hydrocarbons (PAH’s)
- Investigation of 64.5 km of concrete driving surfaces according to LAGA Guideline
- Measurement of all special buildings
- Preparation of detailed calculations about the material composition of each building (mineral residual masses, expected amount of pollutants)
- Creation of detailed (image) documentation including predeveloped coordinates / data for each special building
- Summary of all data, preparation of required overviews